Rodless Cylinder mainly depends on the compressed air flow rate of the cylinder input, the size of the cylinder inlet and outlet, and the size of the inner diameter of the duct. The larger value should be used for high-speed movement. The cylinder movement speed is generally 50-800 mm/s.
For high-speed movement cylinders, a large inner diameter intake pipe should be selected; for load changes, in order to obtain a slow and stable movement speed, a throttling device or a gas-liquid damper can be selected, which is easier to achieve speed control. When using a throttle valve to control the cylinder speed, it should be noted that when a horizontally installed cylinder pushes a load, it is recommended to use exhaust throttling speed control; when a vertically installed cylinder lifts a load, it is recommended to use intake throttling speed control; when the end of the stroke is required to move smoothly to avoid impact, a cylinder with a buffer device should be selected.